ST80328OOOO
New product
Warning: Last items in stock!
Availability date:
L&T, ELECTRONIC TIMER
ST 100Recipient :
* Required fields
or Cancel
COUNTRY OF ORIGIN | INDIA |
Star & Delta starter control circuit diagram wrong
L&t ST100 1st wiring diagram there's no inter lock protection. That is while Running time if you're press ON push button it's to be given got short circuit at Start contactor. So Kindly check the circuit diagram.