12KV ONE ISOLATOR+2 VCB RMU ABB MAKE,OUTDOOR,NON EXTENSIBLE MANUAL OPERATED
DELIVERY 6 WEEKS.
Warning: Last items in stock!
Availability date:
ABB, 12kV CVV RMU
12KV ONE ISOLATOR+2 VCB RMU ABB MAKE,OUTDOOR,NON EXTENSIBLE MANUAL OPERATED
Recipient :
* Required fields
or Cancel
COUNTRY OF ORIGIN | INDIA |
RMU STC RATING | 21KA FOR 3 SECONDS |
RMU EXTENSIBILITY | NON EXTENSIBLE |
RMU CONFIGURATION | TWO VCBs, ONE ISOLATOR |
RMU RELAY | SELF POWERED RELAY |
RMU CURRENT RATING | 630A |
RMU APPLICATION | OUTDOOR IP54 |
RMU OPERATION | MANUAL WITHOUT SCADA CONTACT |
RMU VOLTAGE RATING | 11KV |
SafePlus compact switchgear
Total number of modules 3 pcs
STANDARDS AND MECHANICAL DATA
Metal Enclosed switchgear: IEC 62271-200 General Purpose switches: IEC 60265-1 Disconnectors and Earthing switches: IEC 62271-102 Switch Fuse Combination: IEC 62271-105 Circuit Breakers: IEC 62271-100 Common clauses: IEC 60694 Pressure of SF6 gas: 1.4 bar at 20 °C Cable bushings: DIN 47636 Temperature class: -25 °C - +40 °C outdoor Degree of protection: - SF6 tank: IP 67 - Fusecanisters: IP 67 - Front cover: IP 2X - Cable cover: IP 3X - Enclosure IP 54
Busbars: 240 mm2 Cu Earth bar (external): 120 mm2 Cu - Bolt dimension: M10 Thickness of Stainless Steel Tank: 2.5 mm Colours: - Front cover: RAL 7035 - Side and cable cover: RAL 7035 - Enclosure IS 632
ELECTRICAL DATA – 12 kV - 28kV-1min Nominal voltage: 11 kV Rated frequency: 50 Hz Rated current busbars: 630 A Rated current cable switch disconnector : 630 A Short time withstand current: - cable switch disconnector with interface C (400-bolt) bushing: 20 kArms 3 sec. - vacuum circuit breaker with interface C (400-bolt) bushing: 20 kArms 3 sec. Rated current for transformer T-off : 630 A
Impulse withstand voltage : To earth and between phases: 75 kV Insulation level: - Power frequency 1 min: 28 kV
A01 C Load Break Switch
SafePlus C is a cable switch module with a three position load break switch and earthing switch, busbars, interlocking and earthbar.
1 SafePlus type C: Cable switch 12kV, 630A 1 Manometer 1 Snap action mech. for Manual operation 1 Cable cover standard with Interlocking 1 Cable bushings interface C (400 bolted), 630 A, standard 1 Earth Fault Indicator type EKL 1B 1 Capacitive voltage indication fixed type VPIS 9-15 kV with SCADA Contact 1 Aux. switch for load break switch position 2NO + 2NC 1 Cable support bars, standard for 1-way unit
A02 V Vacuum Circuit Breaker
SafePlus V is a Vacuum circuit breaker module with vacuum circuit breaker, three position isolator/earthing switch, busbars, interlocking, earthbar and stored spring energy mechanism (Amech.).
1 SafePlus type V: Vacuum circuit breaker 12kV, 630A 1 Stored energy mech. for Manual operation 1 Cable cover standard with Interlocking 1 Self Powered Over Current and Earth Fault protection relay type ADR141S 1 Capacitive voltage indication fixed type VPIS 9-15 kV with SCADA Contact 1 Cable bushings interface C (400 bolted), 630A 1 Aux. switch for vacuum circuit breaker position 2NO + 2NC 1 Cable support bars, standard for 1-way unit 3 Ring core current transformer type 150-75/1 A, 2.5VA, 5P10 for protection 1 Additional transformer protection scheme OTI, WTI & Buchholz's relay (Trip and alarm)
A03 V Vacuum Circuit Breaker
SafePlus V is a Vacuum circuit breaker module with vacuum circuit breaker, three position isolator/earthing switch, busbars, interlocking, earthbar and stored spring energy mechanism (Amech.).
1 SafePlus type V: Vacuum circuit breaker 12kV, 630A 1 Stored energy mech. for Manual operation 1 Cable cover standard with Interlocking 1 Self Powered Over Current and Earth Fault protection relay type ADR141S 1 Capacitive voltage indication fixed type VPIS 9-15 kV with SCADA Contact 1 Cable bushings interface C (400 bolted), 630A 1 Aux. switch for vacuum circuit breaker position 2NO + 2NC 1 Cable support bars, standard for 1-way unit 3 Ring core current transformer type 150-75/1 A, 2.5VA, 5P10 for protection 1 Additional transformer protection scheme OTI, WTI & Buchholz's relay (Trip and alarm)
Additional equipment delivered separately or mounted in respective panel.
1 Operating handle
Note : Auxiliary supply for auxilliary relay shall be in Customer’s scope.