New product
12kV SafeLink CB RMU 12kV SafeLink CB RMU ,ABB MAKE
DELIVERY 6 WEEKS.
Warning: Last items in stock!
Availability date:
ABB, 12kV CCV SafeLink CB RMU
12kV SafeLink CB RMU 12kV SafeLink CB RMU ,ABB MAKE
Recipient :
* Required fields
or Cancel
RMU METERING PT | NO PT REQUIRED |
RMU STC RATING | 21KA FOR 3 SECONDS |
RMU MANOMETER | REQUIRED |
RMU EARTH FAULT FPI | NOT REQUIRED |
RMU EXTENSIBILITY | NON EXTENSIBLE |
RMU SHORT CIRCUIT FPI WITH CONTACT | NOT REQUIRED |
RMU CONFIGURATION | ONE VCB, TWO ISOLATORS |
RMU AMMETER REQUIREMENT | NOT REQUIRED |
RMU BATTERY & CHARGER | NOT REQUIRED |
RMU CURRENT RATING | 630A |
RMU ANNUNCIATOR | NOT REQUIRED |
RMU RELAY | SELF POWERED RELAY |
RMU APPLICATION | OUTDOOR IP54 |
COUNTRY OF ORIGIN | INDIA |
RMU SHORT CIRCUIT FPI | NOT REQUIRED |
RMU SCADA COMPATIBILITY | NO |
RMU OPERATION | MANUAL WITHOUT SCADA CONTACT |
RMU VOLTAGE RATING | 11KV |
RMU MULTIFUNCTION METER REQUIREMENT | NOT REQUIRED IN VCB |
HT Panel Outdoor type (RMU UNIT) :- 1 No. 11KV, 400/630A 21KA/3 Sec outdoor type, Non-extensible Manual Operated SF6 gas insulated Ring Main Unit with 2Nos. load Switches 1No. Vacuum Circuit breaker enclosed in a stainless steel tank with self powered microprocessor bases numerical relay and dedicated CT’s for protection of Transformer.-
LOAD BREAK SWITCH 1 :
SafeLink CB C is a cable switch module with a three position load break switch and earthing switch, busbars, interlocking and earthbar with Side Cable Termination
1 SafeLink CB type C: Cable switch 12kV, 630A 1 Manometer 1 Snap action mech. for manual operation 1 Cable cover standard with Interlocking 1 Cable bushings interface C (400 bolted), 630 A, standard 1 Capacitive voltage indication fixed type VPIS 9-15 kV 1 Cable support bars, standard for 1-way unit
LOAD BREAK SWITCH 2 :
SafeLink CB C is a cable switch module with a three position load break switch and earthing switch, busbars, interlocking and earthbar. with Side Cable Termination
1 SafeLink CB type C: Cable switch 12kV, 630A 1 Snap action mech. for manual operation 1 Cable cover standard with Interlocking 1 Cable bushings interface C (400 bolted), 630 A, standard 1 Capacitive voltage indication fixed type VPIS 9-15 kV 1 Cable support bars, standard for 1-way unit
VCB 1 :
SafeLink CB V is a Vacuum circuit breaker module with vacuum circuit breaker, three position isolator/earthing switch, busbars, interlocking, earthbar and stored spring energy with Rear Cable Termination
1 SafeLink CB type V: Vacuum circuit breaker 12kV, 630A 1 Self Powered Over Current and Earth Fault protection relay ADR141S 1 Cable bushings interface C (400 bolted), 630A 1 Capacitive voltage indication fixed type VPIS 6-12 kV 3 Ring core current transformer type 100/1 A, 2.5VA, 5P10 for protection 1 Aux. contacts for VCB & Earth Position 1 Stored energy mech. EL2 for Manual operation