Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual (AS4), On / Off Rocker switch, RYB LED indicator, Motor ON & Trip LED Indicator.
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, On / Off Rocker switch, Motor ON & Trip LED Indicator.
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, On / Off Rocker switch, Motor ON & Trip LED Indicator.
Incorporating Hour meter- Standard Model incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Hour meter (To monitor SPCU power ON hours), rocker switch (ON/OFF Switch) Motor ON & Trip LED Indicator.
Incorporating Hour meter- Standard Model incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Hour meter (To monitor SPCU power ON hours), rocker switch (ON/OFF Switch) Motor ON & Trip LED Indicator.
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Voltmeter with Selector Switch, Suppressed scale Ammeter, Motor ON & Trip LED Indicator, TP 'C' Curve MCB for short circuit protection.
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Voltmeter with Selector Switch, Suppressed scale Ammeter, Motor ON & Trip LED Indicator, TP 'C' Curve MCB for short circuit protection.
Incorporating Heavy Duty 4 Pole Contactor type TC1-DX, Overload relay type LR3D/LR1D, Auto Start Switch, 3 Position selector switch for SPP Auto/SPP Manual / Manual, Voltmeter with Selector Switch, Suppressed scale Ammeter, RYB LED Indicator Motor ON & Trip LED Indicator, TP 'C' curve MCB for short circuit protection.
Incorporating Heavy Duty 4 Pole Contactor type TC1-DX, Overload relay type LR3D/LR1D, Auto Start Switch, 3 Position selector switch for SPP Auto/SPP Manual / Manual, Voltmeter with Selector Switch, Suppressed scale Ammeter, RYB LED Indicator Motor ON & Trip LED Indicator, TP 'C' curve MCB for short circuit protection.
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D/LR1D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Hour meter( To monitor SPCU power ON hours),RYB LED indicator,Motor ON & Trip LED Indicator, TP 'C' curve MCB for short circuit protection
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D/LR1D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Hour meter( To monitor SPCU power ON hours),RYB LED indicator,Motor ON & Trip LED Indicator, TP 'C' curve MCB for short circuit protection
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Hour meter ( To monitor SPCU power ON hours), Motor ON & Trip LED Indicator, TP 'C' curve MCB for short circuit protection.
Incorporating Heavy Duty 4 Pole contactor type TC1-DX, overload relay type LR3D, Auto Start switch, 3 position selector switch for SPP Auto/SPP Manual/Manual, Dual Analog VA Meter, Hour meter ( To monitor SPCU power ON hours), Motor ON & Trip LED Indicator, TP 'C' curve MCB for short circuit protection.
3 Phase Fully Automatic Star Delta Starters in SS Enclosure
3 Phase Fully Automatic Star Delta Starters in SS Enclosure
3 Phase Semi Automatic Star Delta Starters in SS Enclosure
3 Phase Semi Automatic Star Delta Starters in SS Enclosure
Single Phase DOL Starters in SS Enclosure, Incorporating Heavy duty 2 pole Contactor Type AC2D with wide band operating coil and CS1 Type overload relay.
Three Phase DOL Starter in SS Enclosure. CS Series Starters available with contactor type CS1, CS2 & CS3 having 16A, 25A, 32A AC3 duty.
Three Phase DOL Starter in SS Enclosure. CS Series Starters available with contactor type CS1, CS2 & CS3 having 16A, 25A, 32A AC3 duty.